昨天一個客人說她以前有嚴重便祕,大約每隔 10~15 天上一次廁所,後來去看醫生,醫生要她動手術,裝個電子裝置在她腰內,透過不斷刺激達到通便效果,要價幾千澳幣,她回那個醫生:你神經病!
這一二年她來找我按摩,我教她早上起床先喝杯溫水,等個 20 分鐘自然就可以達到通腸的效果,現在便祕的情形已經好轉,幾乎每天早上都會上廁所,最初這個方法只是清消化道的建議,當時我並不知道她便祕。昨天我跟她 說,還好妳是聰明的,沒聽西醫的話,以後再有任何上廁所的困難,先打電話來問我,中醫有很多便宜有效的方法,葯材成本澳幣 5 元有找。(等我拿到執照,就會變成 50 元了,哈哈哈哈哈!) 套句某名醫說的「通大便是最基本的,連大便都清不出來,這個醫生也不要當了。」

下面是電流刺激神經手術的文獻,他們想錢想瘋了。


http://tidsskriftet.no/article/49468/en_GB

Sacral nerve stimulation

S Norderval M Rydningen R-O Lindsetmo D Lein B Vonen 

Summary

Background. Sacral nerve stimulation involves electrical stimulation of a sacral nerve root by means of an electrode and a stimulator. In the course of just a few years, sacral nerve stimulation has become a treatment option for selected patients with urinary retention, urinary incontinence, anal incontinence and constipation. The method is also being tested in connection with several other indications.

Material and methods. The article presents the method and reviews the results of treatment in connection with various indications on the basis of the authors’ own experience and after a non-systematic PubMed search.

Results. An external stimulator is used during a test period of 3 – 30 days, depending on the indication. A positive test (improvement of symptoms by 50 % or more) is achieved by 70 – 90 % of patients with anal incontinence, 70 % with non-obstructive urinary retention, 52 – 77 % with urinary urge incontinence and 43 – 72 % with constipation. Sacral nerve stimulation may also be efficacious in patients with chronic pelvic pain. Following implantation of a stimulator a sustained effect is seen in 50 – 90 % of patients with a positive test response. Up to 75 % of patients will need repeated follow-up in the form of stimulator reprogramming or reoperation due to technical failure. The service life of the stimulator is 3 – 10 years, and it must be replaced surgically when the battery wears out.

Interpretation. Treatment with sacral nerve stimulation may have a sustained effect in patients with various pelvic floor dysfunctions, and appears to be especially efficacious in cases of anal incontinence and non-obstructive urinary retention. Most of the patients will need close follow-up in order to maintain an optimal result.

Permanent electrical stimulation of sacral nerve roots, sacral nerve stimulation (SNS), was first used in the late 1970s by Brindley et al. to treat neurogenic urinary retention (1). Just over ten years later, the first patient series showing positive results from the treatment of this patient group became available (1, 2). The first report on the effect of sacral nerve stimulation in three patients with faecal incontinence was published in 1995 (3).

In 1999, this method was introduced in the University Hospital of North Norway, the first Nordic hospital to do so. Sacral nerve stimulation is now used to treat a number of dysfunctions of the lower urinary tract, the pelvic floor and the bowel, and new indications are being tested. The method is minimally invasive and does not cause any structural changes in the pelvic floor. Even though sacral nerve stimulation is established throughout Norway today, it is our impression that the method is relatively little known in the primary health services, and not even very well known in the specialist health services.

Materials and methods

The article reviews sacral nerve stimulation and treatment results for various indications based on the authors’ own experiences of the method and a review of relevant literature retrieved by way of a non-systematic PubMed search. All the authors of this article perform sacral nerve stimulation at University Hospital of North Norway, and they also participate in the interdisciplinary working group at the Norwegian Continence and Pelvic Floor Centre.

Mechanism

Electrical stimulation is obtained by placing an electrode attached to a stimulator against one of the sacral nerve roots (fig. 1). The voltage used normally ranges from 0.5 to 3 volts, with a frequency of approximately 15 Hz. The effect was initially assumed to be caused by direct stimulation of the bladder muscle, the urethral sphincter and the anal sphincter via motor nerves (3, 4). Later studies, however, indicate that electrical stimulation of the sacral nerve roots causes complex modulation of motor, sensory and autonomous nerve paths in both the central and the peripheral nervous system (5 – 7). The complexity of this active mechanism is the most likely reason why the method can have an effect on several partly conflicting processes.

Figure 1:  Schematic drawing of a woman’s sacrum and pelvis, posterior view. The nerve electrode has been inserted through the third sacral foramen on the right side (solid arrow). The electrode is ideally placed against the third sacral nerve (stippled arrow). The stimulator is placed deeply subcutaneously, and can be seen projected over the right iliac crest.

Powerpoint

Surgical procedure

Currently, only one system for sacral nerve stimulation is commercially available (InterStim, Medtronic, Minneapolis, MS). The surgical procedures are identical irrespective of the indication in question. First, a peripheral nerve evaluation test (PNE test) is undertaken to establish whether the patient will benefit from sacral nerve stimulation. Under general anaesthesia, sedation or local anaesthesia one or several sacral foramina are cannulated, usually foramen 3 or foramen 4. When the cannula is inserted through the sacral foramen, the tip will be located immediately adjacent to the corresponding sacral nerve root (fig. 2).

Figure 2:  Schematic drawing of cannulation of the third sacral foramen on the left side. The tip of the cannula (arrow) will ideally be placed against the corresponding sacral nerve when the cannula is inserted at an angle of 60° to the skin over the sacrum.

Powerpoint

The cannula is supplied with pulsating current from a stimulator. If the operation takes place under general anaesthesia or sedation, the stimulation may lead to contraction of the anal sphincter (fig. 3). If it takes place under local anaesthesia, the stimulation may also cause a sensory response corresponding to the rectum, the bladder or the vagina. If an appropriate response is obtained, an electrode is inserted in the same place using percutaneous technique.

Figure 3:  A cannula has been placed in the third sacral foramen on the left side. The cannula is attached to an electrical cable to test the motoric response of the anal sphincter. Photo: Stig Norderval. The patient has consented to publication of the picture.

Powerpoint

The electrode is linked to an external stimulator that the patient carries during the test period. The duration of this period depends on the patient’s condition. During the test period, the patient keeps a daily record of the frequency of the symptoms. If the test is carried out using a temporary electrode, this can be easily removed by the patient him/herself once the test period is over. If a permanent electrode has been used, the extension wire emerging through the skin at the flank can be cut at the skin level.

After completion of the test, the frequency of the symptoms prior to and during the test are compared. There is a broad agreement that a PNE test should lead to a reduction in symptoms of 50 % or more before implantation of a permanent stimulator is offered.

Two different stimulators are available – one with a service life of up to ten years and another, considerably smaller model, with a service life of 3 – 5 years. The stimulator is implanted deeply subcutaneously in the left or right buttock, according to the patient’s wishes (fig. 4). If the patient was tested using a temporary electrode, a permanent electrode is inserted during the implantation of the stimulator. If a permanent electrode was used for the test, the stimulator will be attached to this electrode. Patients are supplied with a remote control device that enables them to turn the stimulator on and off, change the voltage and switch between up to four different stimulation programmes.

Figure 4:  A permanent stimulator attached to an electrode which has been tunnelled subcutaneously from the third sacral foramen on the right side (arrow) to an established subcutaneous pocket on the right side (stippled arrow). The stimulator is ready to be implanted in the subcutaneous pocket. Photo: Stig Norderval. The patient has consented to publication of the picture.

Powerpoint

Patient selection

Implantation must not be undertaken if there is a skin infection in the area, and a special evaluation must be made if the patient suffers from chronic inflammation of the skin (e.g. psoriasis) or has a weakened immune system. Care should also be taken with regard to persons with personality disorders, since they more often respond poorly in spite of a positive test period (8). In our experience, patients need to be highly motivated to undergo sacral nerve stimulation, and preferably be able to handle the remote control device that controls the stimulator. Furthermore, it is essential that the patients have realistic expectations regarding the results of the treatment, including the possibility of a technical failure and the need for stimulator reprogramming and possibly reoperation.

It has been assumed that persons who are likely to need an MR scan of the pelvic floor region later are not suitable subjects for sacral nerve stimulation. However, studies have failed to establish clearly any undesirable effects for the patients following MR scans (9, 10). This is also our own experience. However, a recent study reports that two patients had their stimulators damaged as a consequence of MR scanning of the pelvic region using a 3-tesla scanner (11). The necessity of an MR scan should therefore be balanced against the risk of damaging the stimulator.

Indications and results

Non-obstructive urinary retention

The first patients who were treated with sacral nerve stimulation suffered from neurogenic urinary retention (partial transverse lesion, multiple sclerosis and stroke) (1, 2). Sacral nerve stimulation can also be efficacious in cases of neurogenic urinary retention due to cauda equina syndrome, prolapse of the intervertebral disc, sequelae after spinal surgery and polyneuropathy (12). The treatment can also be efficacious in cases of idiopathic, non-obstructive urinary retention where other forms of treatment have failed (5, 12, 13).

A positive PNE test response is achieved in approximately 70 % of patients (14), after a test period of 3 – 7 days. Patients with a positive test response achieve a significant reduction of residual urine and use of a catheter once the stimulator is implanted (5, 13). Some studies also show a significant improvement in perceived health (5), healthrelated quality of life and depression score (15). Other studies have been unable to establish such correlations (13). A total of 50 %–80 % of those who have a stimulator implanted are experiencing a beneficial effect 3 – 6 years after the implantation (12 – 14).

Urinary urge incontinence

Urinary urge incontinence is characterized by bouts of a strong and irresistible urge to urinate without the bladder being full. The syndrome may also be accompanied by occasional incontinence (urge incontinence). The condition is initially treated with bladder training and antimuscarinic drugs (16). If this treatment has little effect, sacral nerve stimulation can be attempted.

Sacral nerve stimulation may also be efficacious, irrespective of whether any hyperactivity of the detrusor is detectable or not, in patients both with and without accompanying urinary incontinence (17). A positive PNE test response is achieved in 52 %–77 % of the patients (18) after a test period of 3 – 7 days. In patients who have a stimulator implanted, the effect is sustained in approximately 60 % after 5 – 6 years (12, 13).

Anal incontinence

Sacral nerve stimulation can be indicated in patients with faecal incontinence or gas incontinence combined with an inability to retain faeces when they experience an urge («urgency»), in cases where maximally conservative treatment has been ineffective. The PNE test is conducted over a period of 2 – 3 weeks. A positive test response is achieved for 70 %–90 % of patients (19 – 22). In those who have an implanted stimulator, the effect is sustained in 70 %–90 % after 2 – 5 years (19, 22, 23). Double-blind studies with the stimulator set so that patients were unable to determine whether it was turned on or off have shown that symptoms recur when the stimulator is turned off (24, 25).

The treatment has a positive cost-benefit effect, with a significant improvement in quality of life (26, 27). Patients with sphincter lesions covering up to one-third of the circumference can benefit from sacral nerve stimulation (20). However, sphincter lesions detected by ultrasound are a negative predictor of success (28), and large sphincter defects should probably first be treated by way of sphincter reconstruction.

Constipation

The documentation on the effects of sacral nerve stimulation on chronic constipation is more limited than for the conditions described above. Stimulation of the right or left third sacral nerve root has been shown to increase motility in the left colon and in the rectum (29). An effect has been found in patients suffering from intractable voiding dysfunction with normal and prolonged passage time (30, 31). The PNE test is undertaken over a period of 3 – 4 weeks. A positive PNE test response in cases of chronic constipation is achieved in 43 % – 73 % of patients (30, 32), and the effect is sustained in approximately 90 % after two years (30, 31). A double-blind study with the stimulator set so that patients were unable to determine whether it was turned on or off have shown that symptoms recur when the stimulator is turned off (33).

Other conditions

Sacral nerve stimulation may have an effect on chronic pelvic floor pains, for which all other available treatments have been attempted (34, 35). In a study of nine patients suffering from chronic pains in the anus or rectum, a positive PNE response was obtained for four patients. The median VAS pain score was reduced from 8 to 1, with a sustained effect for more than two years after the implantation of a permanent stimulator (36).

A pilot study has shown that sacral nerve stimulation can be efficacious in patients who are considerably distressed by irritable bowel syndrome (37), and a research group in Århus, Denmark, is currently investigating this in a prospective study.

Sacral nerve stimulation has also been attempted on patients who are at an acute stage after a transverse lesion. Bilateral permanent stimulation may also be efficacious in achieving voiding of the bladder and preventing development of neurogenic bladder dysfunction and motility dysfunction of the colon (38). If this is confirmed, sacral nerve stimulation may be implemented in the early treatment plan for patients with a transverse lesion.

Complications

After implantation, an infection develops in 2 % – 10 % of the patients (19, 39) and leads to removal of the implant in approximately half of the cases. Other complications include pain radiating to the perineum or a lower extremity, pain or discomfort around the stimulator or electrode, dislocation of the electrode with loss of efficacy, or loss of efficacy for no known reason (40, 41). However, this can often be corrected by reprogramming the stimulator, and up to 75 % of the patients will need this (42). Furthermore, 16 % – 54 % of patients will need reoperation, to replace the electrode after technical failure or to move the stimulator because of local discomfort (19, 31, 40, 41). A total of 8 % – 20 % of the patients will eventually have the equipment explanted because of technical failure, pain or discomfort (12, 19, 31, 43).

Follow-up

Since many of the patients will need reprogramming or reoperation, it is essential to have a good and readily available follow-up service (42). At the University Hospital of North Norway we have chosen to let the patient him/herself determine the need for follow-up. In addition, we have established an annual training course, including an offer for checking and possibly reprogramming the stimulator in connection with the course.

Conclusion

Sacral nerve stimulation can be an effective form of treatment of overactive bladder, non-obstructive urinary retention, faecal incontinence, constipation and chronic pain in the pelvic floor area. The treatment is minimally invasive, and the efficacy of the treatment can be determined by means of a brief test period. Most of those who have a stimulator implanted will retain the effect for a number of years. However, many patients will need reprogramming of the stimulator or reoperation to replace the electrode, and this necessitates close follow-up to maintain optimal efficacy.

Main message

  • Sacral nerve stimulation is low-voltage electrical stimulation of a sacral nerve root.

  • Sacral nerve stimulation may be efficacious in treating anal incontinence, various urinary dysfunctions and constipation.

  • A permanent stimulator is implanted only when a test period has demonstrated clear efficacy.

  • Patients with a sacral nerve stimulator will need specialized and ready available follow-up.

arrow
arrow
    全站熱搜

    Cassie Chien 發表在 痞客邦 留言(0) 人氣()